Place water production and use on the same timetable
Record actual production, tank inflow/outflow and overflow on different days rather than use design daily averages alone. Identify prolonged low use and concentrated demand, checking long retention or frequent switching. Responsible personnel should assess reserve and process constraints; theoretical turnover alone does not authorize tank-capacity or operating-level changes.
Supply/demand tables should include major use windows and outlets unused for several days as well as daily totals. Equal reuse volumes in two buildings may create different storage and endpoint conditions if one uses water daily and another only on weekends. Demand timing prevents average-flow sizing from overlooking idle circuits.
Confirm whether the reuse purpose changed during the recording period
Toilet flushing, irrigation, washing and cooling makeup differ in contact and requirements. EPA reuse information organizes risk assessment by final use; one use’s treatment result cannot automatically cover another. Define temporary-water destinations too, preventing tanks labeled for one use from feeding unconfirmed facilities.
Treat the upstream and downstream sides of the tank as separate evaluation points
Treatment-outlet data verify equipment delivery conditions; tank-outlet data describe subsequent storage and distribution. Follow corresponding sampling and test methods, recording storage, blending and use. If only one point changes, investigate its associated stage before replacing every treatment product. One clear appearance or normal odor cannot establish long-term stored-water safety.
Check responsibilities for retreatment and residual control
If subsequent protection or retreatment is needed, identify equipment, products and monitoring locations and conditions outside original design. Route names cannot substitute for validated responsibilities. Check product scope, materials and discharge together; one dose or storage time cannot apply to every reclaimed water.
Require the supply proposal to address both low and high loads
Attach supply/demand curves, tank and outlet diagrams and use documents, asking separately about concentrated demand and prolonged low use. Assess maintenance access, testing and incident response alongside rated treatment flow. Subsequent operating records establish coverage of actual conditions and support future expansion decisions.
Explore further
Does compliant equipment outlet water mean the tank outlet water is compliant?
Do not assume this automatically; validate against use, storage and distribution conditions.
Is an additional disinfection system always necessary?
Check existing treatment, storage and use needs before deciding whether modifications are required.